Lesson 2: Measurement and uncertainty
Back to the unit
Goal
Students tell random error from systematic error and precision from accuracy, see why timing ten swings beats timing one, and calculate a mean and an uncertainty (half the range) from repeated readings.
Materials
- One demonstration pendulum at the front, length 0.60 m (pivot to centre of bob).
- Every student needs a stopwatch or phone timer.
- The worked data below, on a slide or handout.
Steps
Opening (5 min)
Ask: "If ten of you time the same pendulum, will you all get the same number?" Take a show of hands, then test it.
Main activity (35 min)
- Everyone times the same thing (10 min). Start the front pendulum swinging from a small angle. Every student times ten swings at once, starting and stopping on the same count. Collect all the readings on the board. Then repeat with one swing.
If your class's numbers are hard to use, use this example set, ten students timing ten swings:
| Student |
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
| Time for 10 swings (s) |
15.3 |
15.6 |
15.5 |
15.8 |
15.4 |
15.6 |
15.2 |
15.7 |
15.5 |
15.6 |
And three students timing one swing: 1.3 s, 1.8 s, 1.5 s.
- Mean and uncertainty (10 min). Work through the ten-swing set together:
- Mean = 155.2 ÷ 10 = 15.52 s.
- Range = largest − smallest = 15.8 − 15.2 = 0.6 s.
- Uncertainty (half the range) = ±0.3 s.
- Report the mean to the same decimal place as the uncertainty: 15.5 ± 0.3 s for ten swings.
- Divide both by ten for one period: T = 1.55 ± 0.03 s.
Now the single-swing set: mean 1.53 s, half-range 0.25 s, about 16% of the swing. For ten swings the uncertainty is 0.3 s out of 15.5 s, about 2%. Ask students to explain the difference: human reaction times are about 0.2 s (simple reaction times are usually on the order of 200 ms), and that start/stop error is about the same whether you time one swing or ten, so it is a much smaller fraction of a longer time.
- Random vs systematic (10 min). Use two short scenarios:
- Scenario 1: the ten students' readings scatter on both sides of the mean. Some react a little early, some a little late. This is random error: it varies from reading to reading, and repeating and averaging reduces its effect.
-
Scenario 2: one group measured every length to the top of a 4 cm bob instead of its centre, so every length is 2 cm too short. Repeating does not help; every reading is wrong the same way. This is systematic error. It is found by checking the method or the instrument, not by taking more readings.
-
Precision vs accuracy (5 min). Draw two targets on the board:
- Tight cluster away from the centre: precise but not accurate (small random error, a systematic error).
- Wide scatter around the centre: accurate on average but not precise (no systematic error, large random error).
Precision describes random error. The closeness of the mean to the true value (called trueness in the ISO terms) describes systematic error. Good measurements need both.
Discussion questions (with example answers)
- Student G's 15.2 s is the lowest. Was G "wrong"?
Not necessarily. All ten readings are within 0.3 s of the mean; G's is part of the normal scatter, so it stays in. A reading would only be suspicious if it were far outside the others (lesson 3).
- Why not time 100 swings to make the uncertainty even smaller?
It would shrink the reaction-time part further, but the swing slowly dies away, counting errors become likely, and it takes far longer. Ten to twenty swings is a sensible trade-off; a good report says why the number was chosen.
- Would taking more readings fix the "top of the bob" error?
No. It is systematic: more readings give a more precise wrong answer. Fix the method (measure to the centre) or correct each length by adding 2 cm.
- Is ±0.3 s "the error" in the measurement?
It is an estimate of how far the mean could reasonably be off because of scatter. It does not include systematic errors nobody has noticed, so it can be too small.
Closing check (5 min, with answers)
- Times for 10 swings: 12.6 s, 12.9 s, 12.7 s. Find the mean and the uncertainty (half the range). (Mean 38.2 ÷ 3 = 12.73 s ≈ 12.7 s; range 0.3 s; uncertainty ±0.15 s, so about 12.7 ± 0.2 s.)
- Give one example of a systematic error in the pendulum experiment. (Measuring to the top of the bob; a stopwatch that runs fast; always starting the watch late for the same reason.)
- Why does timing ten swings give a smaller percentage uncertainty than timing one? (The reaction-time error is about the same either way but is a smaller fraction of a longer time.)
Vocabulary
random error, systematic error, precision, accuracy, trueness, mean, range, uncertainty, reaction time, significant figures
Differentiation
- Support: give a table with columns for each reading, total, mean, largest, smallest and half-range.
- Stretch: calculate the standard deviation of the ten-swing set (about 0.18 s with a calculator or spreadsheet) and compare it with the half-range. Discuss why courses use different measures of spread.
Safety
- Only the teacher handles the front pendulum; students stay seated while timing.
- Keep the swing area clear.
Teacher notes and misconceptions
- Students often think an uncertainty means someone made a mistake. Stress that every measurement has one; stating it is honest, not an admission of failure.
- "Human error" is not an explanation in a report. Ask: which human action, and does it push readings randomly or always one way?
- Rounding: the closing check answer gives ±0.15 s, which many courses round to ±0.2 s. Accept either if the reasoning is clear.